18650 rechargeable battery lithium 3.7v 3500mah
CH
About Us
Company Profile Development History Sales Network Partner Social Responsibility
Products
Rechargeable Battery Battery Packs Energy Storage Battery Primary Battery Handicraft Article
Subsidiary Company
SINO TECHNOLOGY SUNBEAM GREEN POWER DATAPOWER SEONG-HEE STD
Honor
Qualification Certificate Patent Certificate Honor Certificate
R&D
R&D Center Test Center
News
Company News Industry News
Contact Us
Other information
product
polymer lithium battery Primary battery Rechargeable Battery LR03 alkaline battery
18650 rechargeable battery lithium 3.7v 3500mah
18650 rechargeable battery lithium 3.7v 3500mah

Other information

Home  >  Other information

AG10 battery.Technical requirements of power grid companies for inverters to be connected to distribution grids

release time:2024-03-09 Hits:     Popular:AG11 battery

  

  Distributed power supplies of 10 kV and below are divided into two categories: inverters and rotating motors according to the form of connection to the power grid. Inverter-type distributed power supplies are connected to the grid through inverters, mainly including photovoltaic, full-power inverter grid-connected wind turbines, etc.

  Technical requirements for inverter-type distributed power supply to be connected to 10 kV distribution network

  1. The grid connection point should be equipped with a breaking device that is easy to operate, can be blocked, has obvious breaking points, has a grounding function, and can break fault current.

  2. The inverter should comply with relevant national and industry technical standards, and have the functions of high/low voltage blocking and automatic grid connection when voltage is detected (see Table 1 for voltage protection action time requirements; automatic grid connection when voltage is detected at 85%UN).

  Table 1: Voltage protection action time requirements

  3. When the distributed power supply is connected through a dedicated line, the dedicated line does not need to be equipped or the reclosing switch is disabled.

  4. When the public power grid line is put into automatic reclosing, the reclosing function of detecting no voltage should be added; if the conditions are not met, it should be checked whether the reclosing time cooperates with the distributed power grid connection and off-grid control time (the reclosing time should be set to 2+ δt seconds, δt is the protection cooperation step difference time).

  5. The power factor of distributed power supply should be adjustable within the range of 0.95 (lead) ~ 0.95 (lag).

  Technical requirements for inverter type distributed power supply connected to 220/380 volt distribution network

  1. The grid-connected point should be installed with a low-voltage grid-connected special switch that is easy to operate, has obvious breaking indication, and has the ability to break fault current. The special switch should have the functions of loss-of-voltage tripping and voltage-detection closing. The setting value of the loss-of-voltage tripping should be adjusted It is 20%UN and 10 seconds. The pressure check value should be set to greater than 85%UN.

  2. The inverter should comply with relevant national and industry technical standards, and have the functions of high/low voltage blocking and automatic grid connection when voltage is detected (see Table 1 for voltage protection action time, automatic grid connection at 85%UN when voltage is detected).

  3. When the distributed power access capacity exceeds 25% of the rated capacity of the distribution transformer in the station area, the low-voltage side knife fusion main switch of the distribution transformer should be transformed into a low-voltage main switch, and an anti-islanding device should be installed at the low-voltage busbar of the distribution transformer; the low-voltage main switch The switch should have an operation blocking function with the anti-islanding device. When there is contact between the busbars, the contact switch should also have an operation blocking function with the anti-islanding device.

  4. When the distributed power supply is connected to the 380-volt distribution network, a three-phase inverter should be used; before the distributed power supply is connected to the 220-volt distribution network, the total single-phase connection capacity of the same station should be checked to prevent three-phase Power imbalance condition.

  5. The power factor of distributed power supply should be adjustable within the range of 0.95 (lead) ~ 0.95 (lag).


Read recommendations:

Coin Battery CR 1225

Electronic Protection of Lithium Batteries.polymer lithium battery

Advantages of industrial lithium -ion batteries

701221 battery direct sales

602535 polymer battery

Last article:AG3 battery.Graphene preparation technology is developing rapidly, and industrial production methods

Next article:AG10 battery.Strong "Heart" of Electric Vehicles: Analysis of 4 Battery Technologies

Popular recommendation

12v 300ah lifepo4 battery pack

2023-05-09

522749 lipo battery company

2023-03-22

3.2v lifepo4 battery 200ah

2023-03-22

18650 lithium battery 3000mah

2023-03-22

701221 battery sales

2023-03-22

903242 2500mAh 3.7V

2022-08-23

Lithium Battery LQ-1218

2022-08-19

Lithium Battery LQ12-100

2022-07-29

Ni-MH AAA600mAh 1.2V

2022-07-01

551521 130MAH 3.7V

2023-06-12

Lithium Battery GN12-400

2022-08-19

Elastic sports armband

2022-09-22

R20

2022-08-19

603450 1200MAH 3.7V

2023-06-10

Coin Battery CR 1220

2022-09-27

3.7v 18650 battery pack

2023-06-25

lithium lon battery energy storage system

2023-06-25

CR1130 battery

2023-06-25

CR2032 button cell battery

2023-06-25

polymer lithium battery

2023-06-25

Lithium-ion Batteries with Ternary Materials

2024-11-25

The requirements of the rechargeable battery.9.6kwh energy storage lithium solar battery

2023-03-28

Lithium iron phosphate battery: already mature but not enough

2024-04-16

Lithium battery testing items and methods

2024-05-16

Lithium-Ion Battery Module Design

2025-06-10

AA Dry Battery.18650 lithium-ion battery technology has deficiencies, beware of accidents with mobil

2023-10-13

Can high Lithium batteries reach a battery life of 600km?LR721 battery

2023-06-16

Can lithium batteries reach a battery life of 600km?LR41 battery

2023-06-14

lithium 18650 li ion battery.Precautions for sealing technology of 18650 lithium-ion battery

2023-10-13

Advantages and disadvantages of lithium iron phosphate/lithium cobalate/lithium manganate/ternary li

2022-11-18
360° FACTORY VR TOUR
lithium ion battery 18650 priceWhatsapp
lithium ion battery 18650 price

lithium ion battery 18650 priceTel
+86 19925278095

lithium ion battery 18650 priceEmail
admin@sino-techgroup.com

TOP